ERRP-MIB DEFINITIONS ::= BEGIN
IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Counter32, Unsigned32, TimeTicks
        FROM SNMPv2-SMI
    RowStatus, TruthValue, DisplayString, 
	TEXTUAL-CONVENTION, MacAddress
        FROM SNMPv2-TC
    gbnL2
        FROM ADMIN-MASTER-MIB
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF;

    errpMib MODULE-IDENTITY
        LAST-UPDATED "201012140000Z"
        ORGANIZATION "NEW ADMIN MIB Working Group"
        CONTACT-INFO
                     "Email: support@admin.com"
        DESCRIPTION
                     " The errp MIB is targeted at easing errp configuration via snmp tools."
        REVISION     "1012140000Z"
        DESCRIPTION
                     "Draft 1"
        ::= {gbnL2 7 }

    errpMIBObjects    OBJECT IDENTIFIER ::= { errpMib 1 }
    errp              OBJECT IDENTIFIER ::= { errpMIBObjects 1 }
    
    errpOnoff OBJECT-TYPE
              SYNTAX  INTEGER {
                  enable(1),
                  disable(2)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "Enable/disable errp function for this bridge."
                          --errpʹܿ
              ::= { errp 1 }
    
    errpHealthTime OBJECT-TYPE
              SYNTAX      Integer32(1..10)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The hello timer is used by master or edge node for ring health detection.
                          The correct operational formula: FailedTimer >= 3 * HelloTimer "
                          --ڵͱ߽ڵʹô˶ʱԻ·ԽԼ
              ::= { errp 2 }
  
    errpHealthTimeout OBJECT-TYPE
              SYNTAX      Integer32(3..30)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The timeout value used by master during ring health detection.
                          The correct operational formula: FailedTimer >= 3 * HelloTimer"
                          --ڵ⻷·ʹõĳʱʱֵֵڵHelloTimer3
              ::= { errp 3 }
              
    errpMajorFaultTime OBJECT-TYPE
              SYNTAX      Integer32(2..29)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The timeout value used by assitant edge during ring health detection."
                          --Եڵ⻷·ʹõĳʱʱֵ
              ::= { errp 4 }
                   
    errpPrefwdTimeout OBJECT-TYPE
              SYNTAX      Integer32(3..30)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The block timeout value used by node when portup event occurs."
                          --˿UPʱڵʹõĶ˿ʱʱ
              ::= { errp 5 } 
                      
    errpDomainTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF ErrpDomainEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "A table that contains domain-specific information."
                          --errpɵı              
              ::= { errp 6 }
    
    errpDomainEntry  OBJECT-TYPE
              SYNTAX      ErrpDomainEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "A list of information maintained by every domain."
                          --ÿı
              INDEX       { errpDomainId }
              ::= { errpDomainTable 1 }
              
    ErrpDomainEntry ::=
              SEQUENCE {
                  errpDomainId           Integer32,
                  errpMVlanId            Integer32,
                  errpWorkMode           INTEGER,
                  errpDomainRowStatus    RowStatus
              }
              
    errpDomainId OBJECT-TYPE
              SYNTAX      Integer32(0..15)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The domain ID is used when network is managed in unit of domain, one
                          domain should be a set of contiguous bridges."
                          --IDʱʹãһһڵż
              ::= { errpDomainEntry 1 }
              
    errpMVlanId OBJECT-TYPE
              SYNTAX      Integer32 (1..4093)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The manage VLAN ID of the domain, can not be an existing vlan."
                          --ĹVLAN ID, ÿVLANֱVLANӿVLAN
                          --Э鱨VLANдӻЭ鱨ӿVLANд
                          --ʱֻҪָVLANѱVLAN IDֵ1VLANΪӿVLAN
                          --VLANӿVLANָΪѾڵVLANMACַѧϰģʽΪIVL
              ::= { errpDomainEntry 2 }
    
    errpWorkMode OBJECT-TYPE
              SYNTAX      INTEGER {
                  standard(1),
                  huaWei(2)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The work mode of the domain. If standard(1) is set, then the domain works on RFC3619
                           standard. If huaWei(2) is set, then the domain works on RRPP standard, and is able
                           to work together with the Huawei equipment."
                          --Ĺģʽ
              ::= { errpDomainEntry 3 }
              
    errpDomainRowStatus OBJECT-TYPE
              SYNTAX      RowStatus {
                  active(1),
                  createAndGo(4),
                  destroy(6)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                         "This object is used to create or delete a domain."
              ::= { errpDomainEntry 4 }
              
    errpRingTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF ErrpRingEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "A table that contains domain-and-ring-specific information."
                          --errpɵı
              ::= { errp 7 }
    
    errpRingEntry  OBJECT-TYPE
              SYNTAX      ErrpRingEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "A list of information maintained by every ring."
                          --ÿı
              INDEX       { errpDomainId, errpRingId }
              ::= { errpRingTable 1 }
               
    ErrpRingEntry ::=
              SEQUENCE {
                  errpRingId            Integer32,
                  errpRingLevel         Integer32,
                  errpBrdgRole          INTEGER,
                  errpPriComPortId      Integer32,
                  errpSecEdgePortId     Integer32,
                  errpRingRowStatus     RowStatus,
                  errpNodeState         INTEGER,
                  errpPriComPortState   INTEGER,
                  errpSecEdgePortState  INTEGER,
                  errpQuerySolicit      INTEGER
              }
              
    errpRingId OBJECT-TYPE
              SYNTAX      Integer32 (0..15)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The identifier of ethernet ring which reside in a domain."
                          --̫ID
              ::= { errpRingEntry 1 }
  
    errpRingLevel OBJECT-TYPE
              SYNTAX      Integer32 (0..1)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The ring level,0 means master ring, while 1 means sub ring."
                          --ļ,0Ϊ,1Ϊӻ
              ::= { errpRingEntry 2 }
  
    errpBrdgRole OBJECT-TYPE
              SYNTAX      INTEGER {
                  master(1),
                  trans(2),
                  edge(3),
                  assEdge(4)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "The bridge role in ethernet ring."
                          --ڻеĽɫ
              ::= { errpRingEntry 3 }
    
    errpPriComPortId OBJECT-TYPE
              SYNTAX      Integer32 (1..255)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                         "The primary port id when bridge is master or transmit,the common port id otherwise."
                         --Ϊڵߴڵʱֵ˿,˿
              ::= { errpRingEntry 4 }
              
    errpSecEdgePortId OBJECT-TYPE
              SYNTAX      Integer32 (1..255)
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                         "The secondary port id when bridge is master or transmit,the edge port id otherwise."
                         --Ϊڵߴڵʱֵ˿,߽˿
              ::= { errpRingEntry 5 }
          
    errpRingRowStatus OBJECT-TYPE
              SYNTAX      RowStatus {
                  active(1),
                  notInService(2),
                  notReady(3),
                  createAndGo(4),
                  createAndWait(5),
                  destroy(6)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                         "This object indicates the status of this ring."
                         --ָʾǰĻ״̬
              ::= { errpRingEntry 6 }
              
    errpNodeState OBJECT-TYPE
              SYNTAX      INTEGER {
                  begin(0),
                  health(1),
                  fault(2),
                  linkUp(3),
                  linkDown(4),
                  preforwarding(5)
              }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The node state in the ring. begin(0) means node is inactive or inital state.
                           health(1) means master node detects the ring in a health state.
                           fault(2) means master node detects the ring in a fault state.
                           linkUp(3) means both ring ports of the transmit node are link up and in the forwarding state.
                           linkDown(4) means at least one ring port of the transmit node is link down.
                           preforwarding(5) means at least one ring port of the transmit node is just link up and in the blocking state.
                           Edge node and assistant edge node are same as transmit node, but only concern about the edge port state."
              ::= { errpRingEntry 7 }
              
    errpPriComPortState OBJECT-TYPE
              SYNTAX      INTEGER {
                  disabled(0),
                  forwarding(1),
                  blocking(2)
              }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The primary port or common port state in the ring. disabled(0) means port is link down.
                           forwarding(1) means port is in the forwarding state.
                           blocking(2) means port is in the blocking or discarding state."
              ::= { errpRingEntry 8 }
              
    errpSecEdgePortState OBJECT-TYPE
              SYNTAX      INTEGER {
                  disabled(0),
                  forwarding(1),
                  blocking(2)
              }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The secondary port or edge port state in the ring. disabled(0) means port is link down.
                           forwarding(1) means port is in the forwarding state.
                           blocking(2) means port is in the blocking or discarding state."
              ::= { errpRingEntry 9 }
              
    errpQuerySolicit OBJECT-TYPE
              SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
              }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                          "Enable/disable Query Solicit function of the ring."
              ::= { errpRingEntry 10 }
              
    errpRingStatsTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF ErrpRingStatsEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "This table contains statistics for the ERRP ring ports."
              ::= { errp 8 }
    
    errpRingStatsEntry  OBJECT-TYPE
              SYNTAX      ErrpRingStatsEntry 
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                          "A list of statistics maintained by every ring port. The sequence is:
                           (domain,ring,priComPort),(domain,ring,secEdgePort),
                           (domain,next ring,priComPort),(domain,next ring,secEdgePort),...,
                           (next domain,ring,priComPort),(next domain,ring,secEdgePort),
                           (next domain,next ring,priComPort),......"
              INDEX       { errpDomainId, errpRingId, errpRingPortId }
              ::= { errpRingStatsTable 1 }
              
    ErrpRingStatsEntry ::=
              SEQUENCE {
                  errpRingPortId        Integer32,
                  errpHealthTx          Counter32,
                  errpHealthRx          Counter32,
                  errpCommonFlushTx     Counter32,
                  errpCommonFlushRx     Counter32,
                  errpCompleteFlushTx   Counter32,
                  errpCompleteFlushRx   Counter32,
                  errpLinkDownTx        Counter32,
                  errpLinkDownRx        Counter32,
                  errpLinkUpTx          Counter32,
                  errpLinkUpRx          Counter32,
                  errpEdgeHelloTx       Counter32,
                  errpEdgeHelloRx       Counter32,
                  errpMajorFaultTx      Counter32,
                  errpMajorFaultRx      Counter32
              }
              
    errpRingPortId OBJECT-TYPE
              SYNTAX      Integer32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "The port equals to errpPriComPortId or errpSecEdgePortId of the ring within errpRingTable."
              ::= { errpRingStatsEntry 1 }
  
    errpHealthTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Health(or Hello) packets transmitted on this port."
              ::= { errpRingStatsEntry 2 }
              
    errpHealthRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Health(or Hello) packets received on this port."
              ::= { errpRingStatsEntry 3 }
              
    errpCommonFlushTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Common Flush packets transmitted on this port."
              ::= { errpRingStatsEntry 4 }
              
    errpCommonFlushRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Common Flush packets received on this port."
              ::= { errpRingStatsEntry 5 }
              
    errpCompleteFlushTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Complete Flush packets transmitted on this port."
              ::= { errpRingStatsEntry 6 }
              
    errpCompleteFlushRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Complete Flush packets received on this port."
              ::= { errpRingStatsEntry 7 }
              
    errpLinkDownTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Link Down packets transmitted on this port."
              ::= { errpRingStatsEntry 8 }
              
    errpLinkDownRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Link Down packets received on this port."
              ::= { errpRingStatsEntry 9 }
              
    errpLinkUpTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Link Up packets transmitted on this port."
              ::= { errpRingStatsEntry 10 }
              
    errpLinkUpRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Link Up packets received on this port."
              ::= { errpRingStatsEntry 11 }
              
    errpEdgeHelloTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Edge Hello packets transmitted on this port."
              ::= { errpRingStatsEntry 12 }
              
    errpEdgeHelloRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Edge Hello packets received on this port."
              ::= { errpRingStatsEntry 13 }
              
    errpMajorFaultTx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Major Fault packets transmitted on this port."
              ::= { errpRingStatsEntry 14 }
              
    errpMajorFaultRx OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                          "A count of the number of Major Fault packets received on this port."
              ::= { errpRingStatsEntry 15 }
          
    errpTrap      OBJECT IDENTIFIER ::= { errp 9 }
    ----------------------------------------------------------------------------------
    --ERRP TRAP MIB--
    ----------------------------------------------------------------------------------
                
    errpRingNodeStateChange NOTIFICATION-TYPE
    OBJECTS { errpNodeState }
    STATUS  current
    DESCRIPTION
           "The node state in the ring  turns to health or fault.
             health(1) means master node detects the ring in a health state.
             fault(2) means master node detects the ring in a fault state."
   	::= { errpTrap 1 }
   	
    errpPriComPortStateChange NOTIFICATION-TYPE
    OBJECTS { errpPriComPortState }
    STATUS  current
    DESCRIPTION
           "The primary port or common port state in the ring turns to disabled, forwarding, or blocking.
             disabled(0) means port is link down.
             forwarding(1) means port is in the forwarding state.
             blocking(2) means port is in the blocking or discarding state."
   	::= { errpTrap 2 }

    errpSecEdgePortStateChange NOTIFICATION-TYPE
    OBJECTS { errpSecEdgePortState }
    STATUS  current
    DESCRIPTION
           "The secondary port or edge port state in the ring turns to disabled, forwarding, or blocking.
             disabled(0) means port is link down.
             forwarding(1) means port is in the forwarding state.
             blocking(2) means port is in the blocking or discarding state."
    ::= { errpTrap 3 }
  END