--*    SAGEM SA			 							  				*
--*******************************************************************
--*******************************************************************

--  Filename: shelf
--  File type: .mib    
-- 
--  Description:	SNMPc source Mib file.
--			The MIB module defines structure for ADR equipement family            
--
--  Version:  19 11 2002
--	
--  Date(DD MM YYYY): 15 11 02 last update for IONOS NMS 
--     
--  Contact: D. Mobuchon, F. Bonnevialle
--
--  History: 
--		Version: MIB-P0-301199	Date: 30 11 1999 
-- 
--		Name: F.Bonnevialle	
--		Date: 12 12 2000 
--		Desc: original
--
--		Name: S.LAURENT 	
--		Date: 08 02 2001 
--		Desc: * Change the MIB number: {Sagem 25} -> {Sagem 150}
--            * Add 7 equipment modification counters
--			  * Add a specific index to the table "laserTable"
--			  * Remove the configAction Object
--
--		Name: S.LAURENT 	
--		Date: 18 04 2001 
--		Desc: * Move the 7 equipment modification counters in the Equip Mib
--			   
--		Name: S.LAURENT 	
--		Date: 01 06 2001 
--		Desc: * Replace the BoardIndex Type by INTEGER and BoardFamily Type by a DisplayString.
--			  * Add slotName object in the BoardTable
--	      These modifications allow the MIB to be more independent of the equipment.
--    
--		Name: F.Bonnevialle 	
--		Date: 15 11 2002 		
--		Desc: Modification for SilverCreek Compiler
--
--*******************************************************************
--*******************************************************************
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
--*******************************************************************


SHELF-MIB DEFINITIONS ::= BEGIN

   IMPORTS
   sagemDr								FROM SAGEM-DR-MIB
   SagemBoolean, Severity				FROM EQUIPMENT-MIB
   MODULE-IDENTITY,OBJECT-TYPE, 
   					Counter32      		FROM SNMPv2-SMI
   DisplayString                    	FROM SNMPv2-TC;
   --spiIndex								FROM SDH-ETS-MIB;
   
 
   shelf	MODULE-IDENTITY
      LAST-UPDATED "0012060000Z"
      ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
      CONTACT-INFO
	  ""
      DESCRIPTION    
      "The MIB module specific for ADR equipment"
   ::= { sagemDr 150 }

   -- led
   led		OBJECT IDENTIFIER ::= { shelf 2 }

   -- hold Time
   holdTime		OBJECT IDENTIFIER ::= { shelf 3 }
 
   -- slot and board
   board 		OBJECT IDENTIFIER ::= { shelf 20 }
    
   -- board table
   boardList 	OBJECT IDENTIFIER ::= { shelf 30 }

   -- Software inventory
   softInv		OBJECT IDENTIFIER ::= { shelf 40 }
   
   -- Harware inventory
   hardInv		OBJECT IDENTIFIER ::= { shelf 50 }
      
   -- laser data
   laser		OBJECT IDENTIFIER ::= { shelf 100 }
      
   -- engineering order wire
   eow			OBJECT IDENTIFIER ::= { shelf 120 }

      
        
--*******************************************************************
--*   Slot and  Board
--*******************************************************************
   boardNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of board in equipment."  
      ::= { board 1 } 
   
   boardTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF BoardEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of board in equipment."  
      ::= { board 2 } 
   
   boardEntry   OBJECT-TYPE
      SYNTAX       BoardEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular board of the equipment." 
      INDEX        { boardIndex } 
      ::= { boardTable 1 } 
  

   ProtectionType ::= INTEGER 
   {
    	none(0), 
    	cardp(1)
   }

   BoardFailure ::= INTEGER 
   {
    	none(0), 
    	missing(1), 
    	mismatch(2), 
    	defective(3) 
   }
   
   BoardEntry ::= SEQUENCE 
   { 
   		boardIndex          INTEGER, 
   		boardSlotName       DisplayString, 
   		boardExpectType     INTEGER,                    -- 0 or boardListIndex
   		boardInsertType     INTEGER,                    -- 0 or boardListIndex
   		boardExpectFamily   DisplayString,
   		boardInsertFamily   DisplayString,
   		boardActive         SagemBoolean,
   		boardFirstPortIndex INTEGER,
   		boardProtectionType	ProtectionType,
   		boardMonitor        SagemBoolean,
   		boardFailure        BoardFailure,
   		boardSeverity 	    Severity,  
   		boardMissingSev     Severity,
   		boardMismatchSev    Severity,
   		boardDefectiveSev   Severity
   }

   boardIndex      OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular slot.
	The value of index is a constant assigned to an entry at
	equipment design time. It is usualy related to hardware.
	Each equipment maintain its own pool of values:
	ex ADR155c : A = 1, B = 2, ... M = 5, Fan = 6
	ex ADR2500c: Fan = 1, PSU1 = 2, ...Trib1 = 8, Trib6= 13, Line1 = 14,... 
					Switch2 = 17, Shelf = 18"   
      ::= { boardEntry 1 } 

   boardSlotName     OBJECT-TYPE
      SYNTAX       DisplayString                                 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
   "A DisplayString which identify the name of a particular slot.
   Its value is fixed at equipment design time. 
   It is usualy related to hardware
   ex ADR155c : A, B, ... Fan
   ex ADR2500c: Fan, CCU, CTRL, PSU1, ... TRIB5, .... SWITCH1, ..."
      ::= { boardEntry 2 }
    
   boardExpectType     OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)                         
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
  "A value which configure the expected type. If used, this one must be
  equal to one of existent boardListIndex for the considerated board. Otherwise,
  the value is set to 0.   
  Known types are readable in boardListTable
  "
      ::= { boardEntry 3 }

   boardInsertType     OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)                        
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
   "When the inserted board doesn't match with the expexted board
   the boardMismatch failure is generated.
   The type of the card could be found in hardware inventory."
      ::= { boardEntry 4 }

   boardExpectFamily     OBJECT-TYPE
      SYNTAX       DisplayString                                 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
   "Board Family corresponding to the specified expected kind. This value is send by the equipment.
   ex ADR155c  : 
   ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
   "
      ::= { boardEntry 5 }
 
   boardInsertFamily     OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
   "Board Family corresponding to the type of inserted board.
   ex ADR155c  : 
   ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
   "
      ::= { boardEntry 6 }

   boardActive    OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
   "When the value of this field is set to false, the transmission of 
   this board stop and the board could properly be extracted"
      ::= { boardEntry 7 }  

   boardFirstPortIndex OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
   "If the card is a card with physical ports, then the value is 
    the first index of a physical interface (SPI, PPI) in the mib 
    SDH-ETS. Else, the value is 0."
      ::= { boardEntry 8 }    

   boardProtectionType OBJECT-TYPE
      SYNTAX       ProtectionType
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
   "The value of this field indicates the kind of wanted card protection.
    The default value is NONE.
    if value is changed in cardP(1)then an entry is created in cardpTable. But this table
    has to be completed (by setting the cardpReliefIndex,...) to obtain a configured protection. 
    if value is changed in None(0)then the associated entry in cardpTable is deleted.
    Some cards don't accept any protection. In that case, the value of this field will remain to NONE"
      ::= { boardEntry 9 }    

   boardMonitor    OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
   "When the value of this field is set to false, the failure detection
   is stopped for this board."
      ::= { boardEntry 10 }

   boardFailure   OBJECT-TYPE
      SYNTAX       BoardFailure
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
        "Active failures on board"
      ::= { boardEntry 11 }            
    
   boardSeverity   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
        "A reference to failure severity for boards."
      ::= { boardEntry 12 }
         
         
   boardMissingSev   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
        "A reference to failure severity for boards."
      ::= { boardEntry 13 } 
      
   boardMismatchSev   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
        "A reference to failure severity for boards."
      ::= { boardEntry 14 }
      
   boardDefectiveSev   OBJECT-TYPE
      SYNTAX       Severity
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION
        "A reference to failure severity for boards."
      ::= { boardEntry 15 }          
      
--*******************************************************************
--*   board list
--*******************************************************************    
   boardListNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of entry of the boardList Table"
      ::= { boardList 1 } 
    
   boardListTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF BoardlistEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of board type able to be managed by this equipment .
    In order to manage a new type, just insert the board and if
    the family match with a known family, this table will be
    expand automaticaly with the new type inserted
    
    The XX fist value defined ( with boardSlotName = Shelf = 18 for ADR2500c)
    is a list all possible type of boardInsertedType. 
     "  
      ::= { boardList 2 } 
   
   boardListEntry   OBJECT-TYPE
      SYNTAX       BoardlistEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular boardList of the equipment." 
      INDEX        { boardListIndex } 
      ::= { boardListTable 1 } 

   BoardlistEntry ::= SEQUENCE 
   { 
   		boardListIndex          INTEGER,
   		boardListSlot           INTEGER,
   		boardListType           DisplayString
   }

   boardListIndex  OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value."
      ::= { boardListEntry 1 } 

   boardListSlot  OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the corresponding Slot."
      ::= { boardListEntry 2 } 
   
   boardListType     OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
    "In order to manage a new type, just insert the board and if
    the family match with a known family, this table will be
    expand automaticaly with the new type inserted.
    ex ADR155c :
    ex ADR2500c: 4S1.1, S4.1, L16.2, SWITCH, ..."
      ::= { boardListEntry 3 }


--*******************************************************************
--*   Software inventory
--*******************************************************************     

   softInventoryNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of entry of the softInventory Table"
      ::= { softInv 1 } 
    
   softInventoryTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF SoftInventoryEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of software inventory used "  
      ::= { softInv 2 } 
   
   softInventoryEntry   OBJECT-TYPE
      SYNTAX       SoftInventoryEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular boardList of the equipment." 
      INDEX        { softInventoryIndex } 
      ::= { softInventoryTable 1 } 

   SoftInventoryEntry ::= SEQUENCE 
   { 
   		softInventoryIndex          INTEGER, 
   		softInventoryBoard			INTEGER,        -- boardIndex
   		softInventoryType           DisplayString,
   		softInventoryCode           DisplayString,
   		softInventoryExt            DisplayString
   }

   softInventoryIndex  OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value."
      ::= { softInventoryEntry 1 } 

   softInventoryBoard  OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the corresponding Slot. This variable is needed because some
	 boards have their owns Applicative and Boot codes.  "
      ::= { softInventoryEntry 2 } 
   
   softInventoryType     OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
    "Indication of type software"
      ::= { softInventoryEntry 3 }
   
   softInventoryCode     OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
    "Indication of version code"
      ::= { softInventoryEntry 4 }    
   
   softInventoryExt     OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
    "Indication of extension code. This one is not mandatory."
      ::= { softInventoryEntry 5 }  
     
     
      
 --*******************************************************************
--*   Hardware inventory
--*******************************************************************     
           
   hardInventoryNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of different hardware inventory in equipment."  
      ::= { hardInv 1 } 
   
   hardInventoryTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF HardInventoryEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of hardware inventory in equipment. 
	 A hardware inventory is a description associed to a 
	 particular card"  
      ::= { hardInv 2 } 
   
   hardInventoryEntry   OBJECT-TYPE
      SYNTAX       HardInventoryEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular tInv of the equipment." 
      INDEX        { hardInventoryIndex } 
      ::= { hardInventoryTable 1 } 

   HardInventoryEntry ::= SEQUENCE {
       hardInventoryIndex	 INTEGER,	-- boardIndex
       hardInventoryBoard	 DisplayString,
       hardInventoryDescr    DisplayString
     }
     
   hardInventoryIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
		"Index of the inventory entry that corresponds to a particular slot"  
      ::= { hardInventoryEntry 1 } 
    
   hardInventoryBoard   OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
		"Family of card inserted in the slot"  
      ::= { hardInventoryEntry 2 }       
      
   hardInventoryDescr   OBJECT-TYPE
      SYNTAX       DisplayString
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
		"The content of the inventory: a textual description"  
      ::= { hardInventoryEntry 3 }
      
--*******************************************************************
--*   laser 
--*******************************************************************     
   laserNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of optical interface in equipment."  
      ::= { laser 1 } 
   
   laserTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF LaserEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of synchronous physical interface in equipment."  
      ::= { laser 2 } 
   
   laserEntry   OBJECT-TYPE
      SYNTAX       LaserEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular synchronous physical interface of the equipment." 
--      INDEX        { spiIndex }      
      INDEX        { laserIndex } 

      ::= { laserTable 1 } 
      
   LaserEntry ::= SEQUENCE 
   {
--		spiIndex			INTEGER,     
		laserIndex			INTEGER,            -- =spiIndex
		laserTxEnable		SagemBoolean,
		laserALSEnable		SagemBoolean,
		laserALSRestart2s	SagemBoolean,
		laserALSRestart90s	SagemBoolean
   }
                
   laserIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	" "  
      ::= { laserEntry 1 }  
                
   laserTxEnable   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Enable(true) or disable(false) the laser output of the interface."  
      ::= { laserEntry 2 } 
   
   laserALSEnable   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Automatic Laser Shutdown enable(true) or disable(false).
	When enabled, this function cuts the laser output when a los is
	detected on input signal."  
      ::= { laserEntry 3 }   

   laserALSRestart2s OBJECT-TYPE
      SYNTAX       SagemBoolean  
      MAX-ACCESS   read-write
      STATUS       current  
      DESCRIPTION 
   "Operator command to start a one shot emission during 2s."
      ::= { laserEntry 4 }    

   laserALSRestart90s OBJECT-TYPE 
      SYNTAX       SagemBoolean   
      MAX-ACCESS   read-write 
      STATUS       current   
      DESCRIPTION  
   "Operator command to start a one shot emission during 90s." 
      ::= { laserEntry 5 }           
   -- end laser data   
    
    
--*******************************************************************
--*   Shelf
--*******************************************************************
   adrHotReset   OBJECT-TYPE
      SYNTAX       SagemBoolean
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Software hot reset when this variable is set to TRUE"  
      ::= { shelf 1 }  
      
--*******************************************************************
--*   led
--*******************************************************************    
  LedStatus		::= INTEGER 
   {
    unknown (1), 
    green (2), 
    yellow (3),
    orange (4),
    red (5) 
   }

  LedType		::= INTEGER 
   {    
    status1(1),
    status2(2), 
    online (3),
    traffic(4),
    major  (5),
    minor  (6),
    ether  (7),
    halfFull (8) 
   }
 
   ledNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of led in equipment."  
      ::= { led 1 } 
   
   ledTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF LedEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of led in equipment."  
      ::= { led 2 } 
   
   ledEntry   OBJECT-TYPE
      SYNTAX       LedEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular led of the equipment." 
      INDEX        { ledIndex } 
      ::= { ledTable 1 }                             
                             
   LedEntry ::= SEQUENCE 
   { 
   		ledIndex			INTEGER,
   		ledPosition         INTEGER,   -- boardIndex 
   		ledType				LedType,
   		ledStatus			LedStatus
   }
   
   ledIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular led."  
      ::= { ledEntry 1 }  
      
   ledPosition   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A reference to the associated Board on the equipment."  
      ::= { ledEntry 2 } 
      
   ledType   OBJECT-TYPE
      SYNTAX       LedType
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Type of the Led."  
      ::= { ledEntry 3 }  
      
   ledStatus   OBJECT-TYPE
      SYNTAX       LedStatus
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Status of this Led."  
      ::= { ledEntry 4 }   
      
--*******************************************************************
--* hold time  
--*******************************************************************   
   HoldTime    ::= INTEGER 
   { 
    hold01sec(1), 
    hold03sec(3), 
    hold10sec(10),							 
	hold30sec(30) 
   }  
   
   adrFailHoldOffTime   OBJECT-TYPE
      SYNTAX       HoldTime
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Failure hold off time : the time interval during which the
	defect is present and the failure is not raised"  
      ::= { holdTime 1 } 
   
   adrFailHoldOnTime   OBJECT-TYPE
      SYNTAX       HoldTime
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Failure hold on time : the time interval during which the
	defect is cleared and the failure is not"  
      ::= { holdTime 2 } 



--*******************************************************************
--*   EOW
--*******************************************************************     
   EOWClockMode    ::= INTEGER
   {
   		codirectionnal (0),
   		contradirSlave(1),
   		contradirMaster(2) 
   }     
   
   EOWType    ::= INTEGER
   {
		rsE1 (1), 
		rsF1 (2),
		rsOther(3),
		msE2 (4),
		aux  (5)
   }      
   
   eowNumber   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"Number of EOW port in equipment."  
      ::= {eow 1 } 
   
   eowTable   OBJECT-TYPE
      SYNTAX       SEQUENCE OF EowEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"List of EOW port in equipment."  
      ::= { eow 2 } 
   
   eowEntry   OBJECT-TYPE
      SYNTAX       EowEntry
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION 
	"A particular EOW port of the equipment." 
      INDEX        { eowIndex } 
      ::= { eowTable 1 } 


   EowEntry ::= SEQUENCE 
   {
	eowIndex         	INTEGER,
	eowName          	DisplayString,
    eowSrcType			EOWType,
    eowSrcPtr       	INTEGER, 
    eowSinkType			EOWType,
    eowSinkPtr       	INTEGER,
	eowClockMode     	EOWClockMode
   }
   
   
   eowIndex   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A unique value which identify a particular
	EOW port.
	The value of index is a constant assigned to an entry at
	equipment design time. It is usualy related to harware."  
      ::= { eowEntry 1 } 
   
   eowName   OBJECT-TYPE
      SYNTAX       DisplayString 
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION 
	"A text string which identifies the particular entry among the
	EOW port entries. "  
      ::= { eowEntry 2 } 
   
   eowSrcType   OBJECT-TYPE
      SYNTAX       EOWType
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A reference to the object which sends the data flow to this
	interface. Usually the value is the oid of a vc12 or a connection."  
      ::= { eowEntry 6 } 
     
   eowSrcPtr   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A reference to the object which sends the data flow to this
	interface. Usually the value is the oid of a vc12 or a connection."  
      ::= { eowEntry 7 } 
   
   eowSinkType   OBJECT-TYPE
      SYNTAX       EOWType
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A reference to the object which sends the data flow to this
	interface. Usually the value is the oid of a vc12 or a connection."  
      ::= { eowEntry 8 } 
     
   eowSinkPtr   OBJECT-TYPE
      SYNTAX       INTEGER(0..2147483647)
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"A reference to the object which sends the data flow to this
	interface. Usually the value is the oid of a vc12 or a connection."  
      ::= { eowEntry 9 } 
   
   eowClockMode   OBJECT-TYPE
      SYNTAX       EOWClockMode
      MAX-ACCESS   read-write
      STATUS       current
      DESCRIPTION 
	"Select the direction of the two external synchronisation lines."  
      ::= { eowEntry 10 } 
                                  
END