Package com.google.protobuf
Class DescriptorProtos.FieldDescriptorProto
java.lang.Object
com.google.protobuf.AbstractMessageLite
com.google.protobuf.AbstractMessage
com.google.protobuf.GeneratedMessage
com.google.protobuf.DescriptorProtos.FieldDescriptorProto
- All Implemented Interfaces:
DescriptorProtos.FieldDescriptorProtoOrBuilder,Message,MessageLite,MessageLiteOrBuilder,MessageOrBuilder,Serializable
- Enclosing class:
- DescriptorProtos
public static final class DescriptorProtos.FieldDescriptorProto
extends GeneratedMessage
implements DescriptorProtos.FieldDescriptorProtoOrBuilder
Protobuf type
google.protobuf.FieldDescriptorProto
Describes a field within a message.
- See Also:
-
Nested Class Summary
Nested ClassesModifier and TypeClassDescriptionstatic final classProtobuf typegoogle.protobuf.FieldDescriptorProtostatic enumProtobuf enumgoogle.protobuf.FieldDescriptorProto.Labelstatic enumProtobuf enumgoogle.protobuf.FieldDescriptorProto.TypeNested classes/interfaces inherited from class com.google.protobuf.GeneratedMessage
GeneratedMessage.BuilderParent, GeneratedMessage.ExtendableBuilder<MessageType extends GeneratedMessage.ExtendableMessage,BuilderType extends GeneratedMessage.ExtendableBuilder>, GeneratedMessage.ExtendableMessage<MessageType extends GeneratedMessage.ExtendableMessage>, GeneratedMessage.ExtendableMessageOrBuilder<MessageType extends GeneratedMessage.ExtendableMessage>, GeneratedMessage.FieldAccessorTable, GeneratedMessage.GeneratedExtension<ContainingType extends Message, Type> -
Field Summary
FieldsModifier and TypeFieldDescriptionstatic final intstatic final intstatic final intstatic final intstatic final intstatic final intstatic final intstatic final intstatic final intFields inherited from class com.google.protobuf.GeneratedMessage
alwaysUseFieldBuildersFields inherited from class com.google.protobuf.AbstractMessageLite
memoizedHashCode -
Method Summary
Modifier and TypeMethodDescriptionGet an instance of the type with no fields set.optional string default_value = 7;optional string default_value = 7;static final Descriptors.Descriptoroptional string extendee = 2;optional string extendee = 2;getLabel()optional .google.protobuf.FieldDescriptorProto.Label label = 4;getName()optional string name = 1;optional string name = 1;intoptional int32 number = 3;intoptional int32 oneof_index = 9;optional .google.protobuf.FieldOptions options = 8;optional .google.protobuf.FieldOptions options = 8;Gets the parser for a message of the same type as this message.intGet the number of bytes required to encode this message.getType()optional .google.protobuf.FieldDescriptorProto.Type type = 5;optional string type_name = 6;optional string type_name = 6;final UnknownFieldSetGet theUnknownFieldSetfor this message.booleanoptional string default_value = 7;booleanoptional string extendee = 2;booleanhasLabel()optional .google.protobuf.FieldDescriptorProto.Label label = 4;booleanhasName()optional string name = 1;booleanoptional int32 number = 3;booleanoptional int32 oneof_index = 9;booleanoptional .google.protobuf.FieldOptions options = 8;booleanhasType()optional .google.protobuf.FieldDescriptorProto.Type type = 5;booleanoptional string type_name = 6;protected GeneratedMessage.FieldAccessorTableGet the FieldAccessorTable for this type.final booleanReturns true if all required fields in the message and all embedded messages are set, false otherwise.newBuilder(DescriptorProtos.FieldDescriptorProto prototype) Constructs a new builder for a message of the same type as this message.parseDelimitedFrom(InputStream input) parseDelimitedFrom(InputStream input, ExtensionRegistryLite extensionRegistry) parseFrom(byte[] data) parseFrom(byte[] data, ExtensionRegistryLite extensionRegistry) parseFrom(ByteString data) parseFrom(ByteString data, ExtensionRegistryLite extensionRegistry) parseFrom(CodedInputStream input) parseFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry) parseFrom(InputStream input) parseFrom(InputStream input, ExtensionRegistryLite extensionRegistry) Constructs a builder initialized with the current message.protected ObjectReplaces this object in the output stream with a serialized form.voidwriteTo(CodedOutputStream output) Serializes the message and writes it tooutput.Methods inherited from class com.google.protobuf.GeneratedMessage
getAllFields, getDescriptorForType, getField, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, hasField, hasOneof, makeExtensionsImmutable, newFileScopedGeneratedExtension, newFileScopedGeneratedExtension, newMessageScopedGeneratedExtension, newMessageScopedGeneratedExtension, parseUnknownFieldMethods inherited from class com.google.protobuf.AbstractMessage
equals, findInitializationErrors, getInitializationErrorString, hashCode, hashFields, toStringMethods inherited from class com.google.protobuf.AbstractMessageLite
checkByteStringIsUtf8, toByteArray, toByteString, writeDelimitedTo, writeToMethods inherited from class java.lang.Object
clone, finalize, getClass, notify, notifyAll, wait, wait, waitMethods inherited from interface com.google.protobuf.MessageLite
toByteArray, toByteString, writeDelimitedTo, writeToMethods inherited from interface com.google.protobuf.MessageOrBuilder
findInitializationErrors, getAllFields, getDescriptorForType, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, hasField, hasOneof
-
Field Details
-
PARSER
-
NAME_FIELD_NUMBER
public static final int NAME_FIELD_NUMBER- See Also:
-
NUMBER_FIELD_NUMBER
public static final int NUMBER_FIELD_NUMBER- See Also:
-
LABEL_FIELD_NUMBER
public static final int LABEL_FIELD_NUMBER- See Also:
-
TYPE_FIELD_NUMBER
public static final int TYPE_FIELD_NUMBER- See Also:
-
TYPE_NAME_FIELD_NUMBER
public static final int TYPE_NAME_FIELD_NUMBER- See Also:
-
EXTENDEE_FIELD_NUMBER
public static final int EXTENDEE_FIELD_NUMBER- See Also:
-
DEFAULT_VALUE_FIELD_NUMBER
public static final int DEFAULT_VALUE_FIELD_NUMBER- See Also:
-
ONEOF_INDEX_FIELD_NUMBER
public static final int ONEOF_INDEX_FIELD_NUMBER- See Also:
-
OPTIONS_FIELD_NUMBER
public static final int OPTIONS_FIELD_NUMBER- See Also:
-
-
Method Details
-
getDefaultInstance
-
getDefaultInstanceForType
Description copied from interface:MessageLiteOrBuilderGet an instance of the type with no fields set. Because no fields are set, all getters for singular fields will return default values and repeated fields will appear empty. This may or may not be a singleton. This differs from thegetDefaultInstance()method of generated message classes in that this method is an abstract method of theMessageLiteinterface whereasgetDefaultInstance()is a static method of a specific class. They return the same thing.- Specified by:
getDefaultInstanceForTypein interfaceMessageLiteOrBuilder- Specified by:
getDefaultInstanceForTypein interfaceMessageOrBuilder
-
getUnknownFields
Description copied from interface:MessageOrBuilderGet theUnknownFieldSetfor this message.- Specified by:
getUnknownFieldsin interfaceMessageOrBuilder- Overrides:
getUnknownFieldsin classGeneratedMessage
-
getDescriptor
-
internalGetFieldAccessorTable
Description copied from class:GeneratedMessageGet the FieldAccessorTable for this type. We can't have the message class pass this in to the constructor because of bootstrapping trouble with DescriptorProtos.- Specified by:
internalGetFieldAccessorTablein classGeneratedMessage
-
getParserForType
Description copied from interface:MessageLiteGets the parser for a message of the same type as this message.- Specified by:
getParserForTypein interfaceMessage- Specified by:
getParserForTypein interfaceMessageLite- Overrides:
getParserForTypein classGeneratedMessage
-
hasName
public boolean hasName()optional string name = 1;- Specified by:
hasNamein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getName
optional string name = 1;- Specified by:
getNamein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getNameBytes
optional string name = 1;- Specified by:
getNameBytesin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasNumber
public boolean hasNumber()optional int32 number = 3;- Specified by:
hasNumberin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getNumber
public int getNumber()optional int32 number = 3;- Specified by:
getNumberin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasLabel
public boolean hasLabel()optional .google.protobuf.FieldDescriptorProto.Label label = 4;- Specified by:
hasLabelin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getLabel
optional .google.protobuf.FieldDescriptorProto.Label label = 4;- Specified by:
getLabelin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasType
public boolean hasType()optional .google.protobuf.FieldDescriptorProto.Type type = 5;If type_name is set, this need not be set. If both this and type_name are set, this must be one of TYPE_ENUM, TYPE_MESSAGE or TYPE_GROUP.
- Specified by:
hasTypein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getType
optional .google.protobuf.FieldDescriptorProto.Type type = 5;If type_name is set, this need not be set. If both this and type_name are set, this must be one of TYPE_ENUM, TYPE_MESSAGE or TYPE_GROUP.
- Specified by:
getTypein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasTypeName
public boolean hasTypeName()optional string type_name = 6;For message and enum types, this is the name of the type. If the name starts with a '.', it is fully-qualified. Otherwise, C++-like scoping rules are used to find the type (i.e. first the nested types within this message are searched, then within the parent, on up to the root namespace).
- Specified by:
hasTypeNamein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getTypeName
optional string type_name = 6;For message and enum types, this is the name of the type. If the name starts with a '.', it is fully-qualified. Otherwise, C++-like scoping rules are used to find the type (i.e. first the nested types within this message are searched, then within the parent, on up to the root namespace).
- Specified by:
getTypeNamein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getTypeNameBytes
optional string type_name = 6;For message and enum types, this is the name of the type. If the name starts with a '.', it is fully-qualified. Otherwise, C++-like scoping rules are used to find the type (i.e. first the nested types within this message are searched, then within the parent, on up to the root namespace).
- Specified by:
getTypeNameBytesin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasExtendee
public boolean hasExtendee()optional string extendee = 2;For extensions, this is the name of the type being extended. It is resolved in the same manner as type_name.
- Specified by:
hasExtendeein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getExtendee
optional string extendee = 2;For extensions, this is the name of the type being extended. It is resolved in the same manner as type_name.
- Specified by:
getExtendeein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getExtendeeBytes
optional string extendee = 2;For extensions, this is the name of the type being extended. It is resolved in the same manner as type_name.
- Specified by:
getExtendeeBytesin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasDefaultValue
public boolean hasDefaultValue()optional string default_value = 7;For numeric types, contains the original text representation of the value. For booleans, "true" or "false". For strings, contains the default text contents (not escaped in any way). For bytes, contains the C escaped value. All bytes >= 128 are escaped. TODO(kenton): Base-64 encode?
- Specified by:
hasDefaultValuein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getDefaultValue
optional string default_value = 7;For numeric types, contains the original text representation of the value. For booleans, "true" or "false". For strings, contains the default text contents (not escaped in any way). For bytes, contains the C escaped value. All bytes >= 128 are escaped. TODO(kenton): Base-64 encode?
- Specified by:
getDefaultValuein interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getDefaultValueBytes
optional string default_value = 7;For numeric types, contains the original text representation of the value. For booleans, "true" or "false". For strings, contains the default text contents (not escaped in any way). For bytes, contains the C escaped value. All bytes >= 128 are escaped. TODO(kenton): Base-64 encode?
- Specified by:
getDefaultValueBytesin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasOneofIndex
public boolean hasOneofIndex()optional int32 oneof_index = 9;If set, gives the index of a oneof in the containing type's oneof_decl list. This field is a member of that oneof. Extensions of a oneof should not set this since the oneof to which they belong will be inferred based on the extension range containing the extension's field number.
- Specified by:
hasOneofIndexin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getOneofIndex
public int getOneofIndex()optional int32 oneof_index = 9;If set, gives the index of a oneof in the containing type's oneof_decl list. This field is a member of that oneof. Extensions of a oneof should not set this since the oneof to which they belong will be inferred based on the extension range containing the extension's field number.
- Specified by:
getOneofIndexin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasOptions
public boolean hasOptions()optional .google.protobuf.FieldOptions options = 8;- Specified by:
hasOptionsin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getOptions
optional .google.protobuf.FieldOptions options = 8;- Specified by:
getOptionsin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
getOptionsOrBuilder
optional .google.protobuf.FieldOptions options = 8;- Specified by:
getOptionsOrBuilderin interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
isInitialized
public final boolean isInitialized()Description copied from interface:MessageLiteOrBuilderReturns true if all required fields in the message and all embedded messages are set, false otherwise.- Specified by:
isInitializedin interfaceMessageLiteOrBuilder- Overrides:
isInitializedin classGeneratedMessage
-
writeTo
Description copied from interface:MessageLiteSerializes the message and writes it tooutput. This does not flush or close the stream.- Specified by:
writeToin interfaceMessageLite- Overrides:
writeToin classAbstractMessage- Throws:
IOException
-
getSerializedSize
public int getSerializedSize()Description copied from interface:MessageLiteGet the number of bytes required to encode this message. The result is only computed on the first call and memoized after that.- Specified by:
getSerializedSizein interfaceMessageLite- Overrides:
getSerializedSizein classAbstractMessage
-
writeReplace
Description copied from class:GeneratedMessageReplaces this object in the output stream with a serialized form. Part of Java's serialization magic. Generated sub-classes must override this method by callingreturn super.writeReplace();- Overrides:
writeReplacein classGeneratedMessage- Returns:
- a SerializedForm of this message
- Throws:
ObjectStreamException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(ByteString data) throws InvalidProtocolBufferException - Throws:
InvalidProtocolBufferException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(ByteString data, ExtensionRegistryLite extensionRegistry) throws InvalidProtocolBufferException - Throws:
InvalidProtocolBufferException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(byte[] data) throws InvalidProtocolBufferException - Throws:
InvalidProtocolBufferException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(byte[] data, ExtensionRegistryLite extensionRegistry) throws InvalidProtocolBufferException - Throws:
InvalidProtocolBufferException
-
parseFrom
- Throws:
IOException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(InputStream input, ExtensionRegistryLite extensionRegistry) throws IOException - Throws:
IOException
-
parseDelimitedFrom
public static DescriptorProtos.FieldDescriptorProto parseDelimitedFrom(InputStream input) throws IOException - Throws:
IOException
-
parseDelimitedFrom
public static DescriptorProtos.FieldDescriptorProto parseDelimitedFrom(InputStream input, ExtensionRegistryLite extensionRegistry) throws IOException - Throws:
IOException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(CodedInputStream input) throws IOException - Throws:
IOException
-
parseFrom
public static DescriptorProtos.FieldDescriptorProto parseFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry) throws IOException - Throws:
IOException
-
newBuilder
-
newBuilderForType
Description copied from interface:MessageLiteConstructs a new builder for a message of the same type as this message.- Specified by:
newBuilderForTypein interfaceMessage- Specified by:
newBuilderForTypein interfaceMessageLite
-
newBuilder
public static DescriptorProtos.FieldDescriptorProto.Builder newBuilder(DescriptorProtos.FieldDescriptorProto prototype) -
toBuilder
Description copied from interface:MessageLiteConstructs a builder initialized with the current message. Use this to derive a new message from the current one.- Specified by:
toBuilderin interfaceMessage- Specified by:
toBuilderin interfaceMessageLite
-
newBuilderForType
protected DescriptorProtos.FieldDescriptorProto.Builder newBuilderForType(GeneratedMessage.BuilderParent parent) - Specified by:
newBuilderForTypein classGeneratedMessage
-