# General Structure

(sec-yaml-sections)=
## Sections

The top level of a Cantera [YAML](https://yaml.org/spec/1.2/spec.html#Introduction)
input file is a mapping that defines different input file sections. Each section
consists of a list of mappings that define objects of the same type, such as reactions,
species, phases, or elements. The `phases` section of an input file contains all of the
phase definitions. Multiple sections containing reaction, species, or element
definitions can be used. The specific names `reactions`, `species`, and `elements` are
used as defaults when looking for [](sec-yaml-reactions), [](sec-yaml-species), and
[](sec-yaml-elements) to add to a phase. A simple input file has the following
structure:

```yaml
phases:
- name: spam
  thermo: ideal-gas
  # Additional fields come after this
- name: green-eggs
  thermo: model-name
  # Additional fields come after this

species:
- name: A
  # Additional fields come after this
- name: B
  # Additional fields come after this
- name: C
  # Additional fields come after this

reactions:
- equation: A + B <=> C + D
  # Additional fields come after this
- equation: A + C <=> 2 D
  # Additional fields come after this
```

(sec-yaml-units)=

## Units

While Cantera generally works internally in SI units, input values can be provided using
a number of different units.

Compound units are written using the asterisk (`*`) to indicate multiplication, the
forward slash (`/`) to indicate division, and the caret (`^`) to indicate
exponentiation. Exponents can include negative and decimal values. Standard one-letter
metric prefixes can be applied to any unit. Supported base units are:

- Mass: `g`
- Length: `m`, `micron`, `angstrom`, `Å`
- Time: `s`, `min`, `hr`
- Temperature: `K`, `C`
- Current: `A`
- Quantity: `mol` (gram mole), `gmol`, `mole`, `kmol`, `kgmol`, `molec`

Supported compound units are:

- Energy: `J`, `cal`, `erg`, `eV`
- Activation Energy: `K`, any unit of energy per quantity (`J/kmol`,
  `cal/mol`, etc.), or any unit of energy (such as `eV`)
- Force: `N`, `dyn`
- Pressure: `Pa`, `atm`, `bar`, `dyn/cm^2`
- Volume: `m^3`, `m³`, `liter`, `L`, `l`, `cc`
- Other electrical units: `ohm`, `V`, `coulomb`

Units can be specified on individual input values by placing them after the value,
separated by a space:

```yaml
{A: 1.45e9 cm^3/kmol, b: 0.4, Ea: 21033 kJ/kmol}
```

or by using a `units` mapping:

```yaml
units: {mass: g, quantity: mol, pressure: atm, activation-energy: cal/mol}
```

A `units` mapping will set the default units for all values within the same YAML list or
mapping, including any nested lists and mappings. Units not specified by a mapping use
the values from higher level mappings, or the Cantera defaults if no `units` mapping
specifies applicable units. If a `units` mapping appears in a list, it must be the first
item in that list.

Default units may be set for `mass`, `length`, `time`, `temperature`, `current`,
`quantity`, `pressure`, `energy`, and `activation-energy`. The units `pressure` and
`energy` are used when these units appear explicitly in the units that a value is being
converted to within Cantera. For example, a conversion to `N/m^2` will use the default
units for mass, length, and time, while a conversion to `Pa` will use the default units
for pressure.

Activation energies given in temperature units will be implicitly converted to energy
per quantity by dividing by the gas constant. Activation energies given in pure energy
units such as eV will be converted to energy per quantity by multiplying by the Avogadro
constant. Setting default units for `energy` and `quantity` will determine the default
units of `activation-energy`, which can be overridden by explicitly giving the desired
units of `activation-energy`.